Skip to main content
search

Hydroxyl Radical Systems

Specifications

PICO SPECIFICATIONS

Specifications PICO
Maximum Oxidant Output: 20 g/hr
Maximum Number of Nozzles: 1 LV Nozzle
Maximum Treatment Volume*:
*Maximum treatment volume is dependent on application.
1,000 ft³
Maximum Distance Between Nozzle & Unit*:
*Maximum distance based on a straight line. Actual distance may be affected by elevation and bends.
150 ft
NOZZLE PROPERTIES
LV Nozzle
Average Air Output: 1.5 CFM
Water Usage: 1.5 gal/hr
PHYSICAL PROPERTIES
Enclosure TGIC Polyester Powder Coated Aluminum
Unit Dimensions, with Pedestal (LxWxH): 20 x 18 x 32
Installation Wall or Pole Mount
Unit Weight: 55-75 lbs
OPERATING TEMPERATURE 20°F to 100°F
POWER SUPPLY 110-120 VAC, 15A, 60 Hz, Single Phase
WATER SUPPLY
Quality: Potable
Minimum Supply: 2 gal/hr
Minimum Water Pressure: 25 psi
Maximum Water Pressure: 75 psi

NANO SPECIFICATIONS

Specifications NANO
Maximum Oxidant Output: 20 g/hr
Maximum Number of Nozzles: 2
Maximum Treatment Volume*:
*Maximum treatment volume is dependent on application.
10,000 ft³
Maximum Distance Between Nozzle & Unit*:
*Maximum distance based on a straight line. Actual distance may be affected by elevation and bends.
300 ft
NOZZLE PROPERTIES
LV Nozzle
Average Air Output: 1.5 CFM
Water Usage: 1.5 gal/hr
HV Nozzle
Average Air Output: 30-40 CFM
Water Usage: 8 gal/hr
PHYSICAL PROPERTIES
Enclosure TGIC Polyester Powder Coated Aluminum
Unit Dimensions, with Pedestal (LxWxH): 50 in x 33 in x 69 in
Minimum Installation Pad: 72 in x 72 in x 4 in
Unit Weight: 200-400 lbs
OPERATING TEMPERATURE 20°F to 100°F
POWER SUPPLY 208-240 VAC, 30A, 60 Hz, Single Phase
WATER SUPPLY
Quality: Potable
Minimum Supply: 10 gal/hr per nozzle
Minimum Water Pressure: 25 psi
Maximum Water Pressure: 75 psi

MICRO SPECIFICATIONS

Specifications MICRO
Maximum Oxidant Output: 50 g/hr
Maximum Number of Nozzles: 4
Maximum Treatment Volume*:
*Maximum treatment volume is dependent on application.
26,000 ft³
Maximum Distance Between Nozzle & Unit*:
*Maximum distance based on a straight line. Actual distance may be affected by elevation and bends.
300 ft
NOZZLE PROPERTIES
LV Nozzle
Average Air Output: 1.5 CFM
Water Usage: 1.5 gal/hr
HV Nozzle
Average Air Output: 30-40 CFM
Water Usage: 8 gal/hr
PHYSICAL PROPERTIES
Enclosure TGIC Polyester Powder Coated Aluminum
Unit Dimensions, with Pedestal (LxWxH): 50 in x 33 in x 69 in
Minimum Installation Pad: 72 in x 72 in x 4 in
Unit Weight: 200-400 lbs
OPERATING TEMPERATURE 20°F to 100°F
POWER SUPPLY 208-240 VAC, 30A, 60 Hz, Single Phase
WATER SUPPLY
Quality: Potable
Minimum Supply: 10 gal/hr per nozzle
Minimum Water Pressure: 25 psi
Maximum Water Pressure: 75 psi

MILLI SPECIFICATIONS

Specifications MILLI
Maximum Oxidant Output: 60 g/hr
Maximum Number of Nozzles: 6
Maximum Treatment Volume*:
*Maximum treatment volume is dependent on application.
42,000 ft³
Maximum Distance Between Nozzle & Unit*:
*Maximum distance based on a straight line. Actual distance may be affected by elevation and bends.
300 ft
NOZZLE PROPERTIES
LV Nozzle
Average Air Output: 1.5 CFM
Water Usage: 1.5 gal/hr
HV Nozzle
Average Air Output: 30-40 CFM
Water Usage: 8 gal/hr
PHYSICAL PROPERTIES
Enclosure TGIC Polyester Powder Coated Aluminum
Unit Dimensions, with Pedestal (LxWxH): 50 in x 33 in x 69 in
Minimum Installation Pad: 72 in x 72 in x 4 in
Unit Weight: 200-400 lbs
OPERATING TEMPERATURE 20°F to 100°F
POWER SUPPLY 208-240 VAC, 30A, 60 Hz, Single Phase
WATER SUPPLY
Quality: Potable
Minimum Supply: 10 gal/hr per nozzle
Minimum Water Pressure: 25 psi
Maximum Water Pressure: 75 psi
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.